Journal profile
Journal of Artificial Organs
- Papers published
- 1,603
- Citations
- 19K
- h-index
- 50
- 2-yr mean citations
- 1.56
- Open access
- 14%
Most cited
Landmark papers in Journal of Artificial Organs
- 2005Journal of Artificial Organs394 citationsOpenAlex
Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review
Hiroaki Haruguchi, Satoshi Teraoka
2003Journal of Artificial Organs304 citationsOpenAlexDrug targeting with nano-sized carrier systems
Masayuki Yokoyama
2005Journal of Artificial Organs232 citationsOpenAlexClinical benefits and risk analysis of topical hemostats: a review
2005Journal of Artificial Organs220 citationsOpenAlexExtracorporeal cytokine elimination as rescue therapy in refractory septic shock: a prospective single-center study
Sigrun Friesecke, Stephanie-Susanne Stecher, Stefan Groß, Stephan Burkhard Felix +1 more
2017Journal of Artificial Organs198 citationsOpenAlexDevelopment of an electrostatic generator for a cardiac pacemaker that harnesses the ventricular wall motion
Ryoichi TASHIRO, Nobuyuki Kabei, Kunimasa Katayama, Eiichi Tsuboi +1 more
2002Journal of Artificial Organs155 citationsOpenAlexPlatelet and growth factor concentrations in activated platelet-rich plasma: a comparison of seven commercial separation systems
Satoshi Kushida, Natsuko Kakudo, Naoki Morimoto, Tomoya Hara +3 more
2014Journal of Artificial Organs152 citationsOpenAlexMaxillofacial reconstruction using custom-made artificial bones fabricated by inkjet printing technology
Hideto Saijo, Kazuyo Igawa, Yuki Kanno, Yoshiyuki Mori +9 more
2009Journal of Artificial Organs146 citationsOpenAlex
Latest
Recently published
Association between pre-processing total protein and processing time in drop-type cell-free and concentrated ascites reinfusion therapy
Kazuha Sagiya, Naoki Ogasawara, Shinya Inahara, 高橋瞭太 +5 more
2026Journal of Artificial Organs0 citationsOpenAlexCorrection: Extracorporeal life support for severe heart failure in a diffuse panbronchiolitis patient awaiting lung transplant: a case report
Yoshikazu Kimura, Shuji Okahara, Haruki Sunami, Shin Tanaka +3 more
2026Journal of Artificial Organs0 citations Open accessOpenAlexModerate therapeutic hypothermia with mechanical left ventricular unloading on non-infarct area in an acute myocardial infarction model
Shusuke Imaoka, Masashi Kawamura, Akima Harada, Kei Ishikawa +9 more
2026Journal of Artificial Organs0 citationsOpenAlexSuccessful management of long-term venovenous ECMO for severe PARDS in a child with acute lymphoblastic leukemia
Hasan Özen, Gülçin Karaçoban, Fevzi Kahveci, Hasan Fatih Çakmaklı +3 more
2026Journal of Artificial Organs0 citationsOpenAlexImpact of draining cannula position and configuration under high-flow extracorporeal CO2 removal (ECCO2R) on recirculation and extracorporeal decarboxylation
Jonathan Charbit, Clara Muller, Mehdi Girard, Elie Courvalin +5 more
2026Journal of Artificial Organs0 citations Open accessThe main goal of the present study was to demonstrate the influence of draining cannulas’ position and high-flow extracorporeal CO 2 removal ( ECCO 2 R) configuration on recirculation and extracorporeal decarboxylation. This single-center retrospective study was conducted between January 2018 and May 2024. All patients who received a high-flow ECCO 2 R (extracorporeal blood flow ≥ 2 L/min) were included. Four configurations each used an ECMO device, two single-lumen cannulas, and an ipsilateral cannulation site: CENTRAL DRAINAGE configurations ( central jugular-jugular and central femoro-femoral ), DISTAL DRAINAGE configurations ( distal jugular-jugular and distal femoro-femoral ). Recirculation coefficient and CO 2 elimination were assessed between these configurations. The influence of the configuration and recirculation coefficient on CO 2 elimination was studied by multivariable mixed linear model. Eighteen patients were treated with high-flow ECCO 2 R. Extracorporeal blood flows (median of 2.6 L/min [IQR, 2.0‒2.6 L/min]) were comparable between the configurations ( P = 0.33), although values higher than 2.5 L/min were observed in CENTRAL DRAINAGE configurations. Median CO 2 elimination was 110 mL(STPD)/min (IQR, 83‒149 mL(STPD)/min). Recirculation coefficient was significantly higher with the DISTAL DRAINAGE configurations (59% [IQR, 51‒71%] versus 9% [IQR, 15‒22%], respectively; P < 0.001). Consequently, CO 2 elimination was significantly lower with the DISTAL DRAINAGE configurations (58 mL(STPD)/min [IQR, 44‒72 mL(STPD)/min] versus 122 mL(STPD)/min [IQR, 96‒159 mL(STPD)/min], respectively; P = 0.003). Both DISTAL DRAINAGE configurations and high recirculation coefficient were significantly associated in multivariable analysis with a reduction in CO 2 elimination ( P < 0.001). We evaluated four different configurations of high-flow ECCO 2 R using single-lumen cannulas allowing either a central or a distal drainage. A central drainage configuration gave better rheological conditions and lower recirculation, leading to better extracorporeal decarboxylation.
OpenAlexAxillary microaxial flow pump support for stepwise source control and bridge to durable left ventricular assist device therapy in cardiac device–related infective endocarditis
Yohei Tamura, 中原 志朗, Masahito Saito, Kei Torikai +2 more
2026Journal of Artificial Organs0 citationsOpenAlexPre-cannulation ventilation duration and the trajectory of venovenous extracorporeal membrane oxygenation in COVID-19-related acute respiratory distress syndrome: a nationwide competing-risks cohort study
Takahiro Masuda, Akihiro Hirakawa, on behalf of Japan ECMOnet for COVID-19
2026Journal of Artificial Organs0 citations Open accessPURPOSE: Pre-cannulation ventilation duration is often considered in selecting candidates for venovenous extracorporeal membrane oxygenation, but its relationship with the subsequent support trajectory is uncertain. We examined associations with first liberation, death before liberation, and time on support. METHODS: We analyzed a nationwide Japanese registry of patients receiving venovenous extracorporeal membrane oxygenation for COVID-19-related acute respiratory distress syndrome. First liberation and death before liberation were treated as competing transitions over 90 days. Cause-specific Cox models were stratified by epidemic period and adjusted for age, sex, and body mass index. Expected time on support was calculated from state-occupancy probabilities. RESULTS: Among 1,420 patients, the adjusted hazard ratio for first liberation relative to 0-1 days was 0.87 (95% confidence interval 0.72-1.05) for 2-3 days, 0.65 (0.54-0.78) for 4-7 days, 0.41 (0.32-0.52) for 8-14 days, and 0.58 (0.34-0.98) for at least 15 days. The association was strongest during the first 14 days. Death before liberation, which does not represent overall mortality because follow-up after liberation was short, showed no monotonic gradient below 15 days. Expected time on support was 26.9 days after more than 7 days of ventilation and 18.4 days after 7 days or less. CONCLUSIONS: Among selected recipients, longer pre-cannulation ventilation, particularly 8-14 days, was associated with slower early liberation and longer support. It may inform the anticipated course and resource requirements after cannulation, but does not define a candidacy threshold.
OpenAlexResolution of restless legs syndrome after postdilution online hemodiafiltration using a vitamin E-bonded polysulfone membrane: a report of two cases
Masayuki Kimura, Naomi Morita, Kazuyoshi Karasuda, Kazuomi Yamashita +1 more
2026Journal of Artificial Organs0 citationsOpenAlexExtracorporeal cardiopulmonary resuscitation for cardiogenic shock in a Jehovah’s witness
Derek Afflu, Louis F. Chai, Hiromu Kehara, Sean M Baskin +2 more
2026Journal of Artificial Organs0 citations Open accessVeno-arterial (V-A) and veno-venous (V-V) extracorporeal membrane oxygenation (ECMO) are frequently employed in the management of cardiopulmonary failure in critically ill patients. Utilization, however, is controversial in the Jehovah's Witness (JW) population as temporary mechanical circulatory support (tMCS) typically is associated with blood loss requiring transfusions. Despite this fact, use of ECMO is still feasible in this population while avoiding blood transfusions and there have been few reported cases in the literature. However, its use as part of cardiopulmonary resuscitation is limited. Multiple strategies have been employed to limit blood loss and maximize endogenous hematopoiesis to assist in maintaining normal physiology while utilizing tMCS. Though these tactics are most useful when applied in the preintervention setting, they are applicable in the emergency setting including extracorporeal cardiopulmonary resuscitation (ECPR). This can be achieved with conscientious cannulation technique and circuit management. Presented here is a case report of the successful use of V-A ECMO in the resuscitation for a JW, avoiding blood product transfusions. The protocol utilized to eliminate the need for blood transfusions is also discussed. This approach adds to the growing body of evidence emphasizing that the use of tMCS as part of bloodless medicine practice is feasible, even in the emergency setting.
OpenAlexImpella purge solutions in patients receiving extracorporeal membrane oxygenation
Nathaniel J. Martin, Christoph S. Nabzdyk, Scott D. Nei, Andrew N. Rosenbaum +2 more
2026Journal of Artificial Organs0 citationsOpenAlex

