EPIDEMIC DENGUE 1 IN BRAZIL, 1986: EVALUATION OF A CLINICALLY BASED DENGUE SURVEILLANCE SYSTEM
VANCE J. DLETZa b c d, DUANE J. GUBLERc e f g✉, José G. Rigau-Péreza h, FRANCISCO PINHEIROi j, Hermann Gonçalves Schatzmayrk, RAYMOND E. BAILEYe f, Robert A. Gunna h
- aEpidemiology Program Office, Division of Field Services, Centers for Disease Control Atlanta, GA
- bPresently with Expanded Program on Immursization, Pan American Health Organization Mexico City, Mexico
- cSan Juan Laboratories, Dengue Branch, Division of Vector-borne Infectious Diseases, Center for Infectious Diseases, Centers for Disease Control San Juan, PR
- dDivision of Vector-borne Infectious Diseases, Centers for Disease Control, San Juan, PR
- eDivision of Vector-borne Infectious Diseases, Center for Infectious Diseases, Centers for Disease Control Fort Collins, CO
- fDivision of Vector-borne Infectious Diseases, Center for Infectious Diseases, Centers for Disease ControlFort Collins, CO
- gSan Juan Laboratories, Dengue Branch, Division of Vector-borne Infectious Diseases, Center for Infectious Diseases, Centers for Disease ControlSan Juan, PR
- hEpidemiology Program Office, Division of Field Services, Centers for Disease ControlAtlanta, GA
- i
Papers open inside SciRah from the original publisher or repository; SciRah never hosts them.
Abstract
In the last 15 years, dengue fever has emerged as a major health problem in tropical America. Prevention and control of epidemic disease are enhanced by the rapid identification of new or increased dengue activity. Most surveillance systems, however, identify cases by clinical case reports and, therefore, lack the sensitivity needed for early detection. During the 1986 dengue 1 epidemic in Rio de Janeiro, Brazil, the authors evaluated the usefulness of a clinical case definition by comparing it with laboratory-confirmed infection status of residents in two cities. The case definition had a sensitivity of 64% and a false-positive rate of 57%. Thus, for every 100 laboratory-confirmed dengue infections, 230 cases were reported. Both infected and noninfected residents who used medical services and who lived in the city with the highest transmission were more likely to meet the case definition. Thus, factors unrelated to actual infection influenced the sensitivity. With the use of stepwise logistic regression, the authors analyzed combinations of patient symptoms and produced nine new hypothetical case definitions. However, none of the new definitions had a false-positive rate lower than 38%. This study emphasizes the need for laboratory-based dengue surveillance systems.

