Laboratory-Generated DNA Can Cause Anomalous Pathogen Diagnostic Test Results
Lindsey R. Robinson‐McCarthya b, Alexander J. Mijalisa b, Gabriel T. Filsingerc d, Helena de Puige f g, Nina M. Donghiaf, Thomas E. Schausf, Robert A. Rasmussenf, Raphaël Ferreiraa b f, Jeantine E. Lunshoff h i j, George Chaoa b, Dmitry Ter‐Ovanesyanf,
Papers open inside SciRah from the original publisher or repository; SciRah never hosts them.
Abstract
To meet the challenges imposed by the COVID-19 pandemic, research laboratories shifted their focus and clinical diagnostic laboratories developed and utilized new assays. Nucleic acid-based testing became widespread and, for the first time, was used as a prophylactic measure. We report 15 cases of researchers at two institutes testing positive for SARS-CoV-2 on routine surveillance tests, in the absence of any symptoms or transmission. These researchers were likely contaminated with nonhazardous nucleic acids generated in the laboratory in the course of developing new SARS-CoV-2 diagnostics. These contaminating nucleic acids were persistent and widespread throughout the laboratory. We report these findings as a cautionary tale to those working with nucleic acids used in diagnostic testing and as a call for careful stewardship of diagnostically relevant molecules. Our conclusions are especially relevant as at-home COVID-19 testing gains traction in the marketplace and these amplicons may impact on the general public.