Ratio of neutrophilic CD64 and monocytic HLA‐DR : A novel parameter in diagnosis and prognostication of neonatal sepsis
Richeek Pradhana b c, Paresh Jaind e, Anshuman Pariab f, Anindya Kumar Sahab f, Jagdish Prasad Sahoob f, Anway Senb g h, Suchandra Mukherjeeb f, Tapas Kumar Somb f, Avijit Hazraa b c, Noel L. Warneri j, Arun Kumarendu Singhb f, Mitali Chatterjeea b c✉
- aDepartment of Pharmacology Institute of Postgraduate Medical Education &
- bResearch 244 B Acharya JC Bose Road Kolkata 700 020 India
- cDepartment of Pharmacology, Institute of Postgraduate Medical Education & Research, 244 B Acharya JC Bose Road, Kolkata, 700 020, India
- dBD Biosciences India Gurgaon Haryana 122001 India
- eBD Biosciences India Gurgaon, Haryana, 122001, India
- fDepartment of Neonatology Institute of Postgraduate Medical Education &
- gDepartment of Pathology Institute of Postgraduate Medical Education &
- hDepartment of Pathology, Institute of Postgraduate Medical Education & Research, 244 B Acharya JC Bose Road, Kolkata, 700, 020, India
- iBD Biosciences San Jose San Jose California 95131
- jBD Biosciences San Jose, San Jose, California, 95131
- ✉Corresponding author
Papers open inside SciRah from the original publisher or repository; SciRah never hosts them.
Abstract
OBJECTIVE: Approaches to monitoring of sepsis have traditionally relied upon the pro-inflammatory component of the sepsis response. This study evaluated the diagnostic and prognostic potential of the ratio of neutrophilic CD64 (nCD64) and monocytic HLA-DR (mHLA-DR) median fluorescence index in monitoring of neonatal sepsis. METHODS: Blood from 100 neonates suspected of sepsis and 29 healthy controls was collected on clinical suspicion of sepsis, and the expression of nCD64, mHLA-DR was evaluated by Flow Cytometry; thereby, a derived parameter "Sepsis index," SI = nCD64/mHLA-DR × 100 was estimated. RESULTS: At day 1, sensitivity and specificity to detect sepsis using nCD64 was 73.01% and 89.18%, respectively, while for SI it was 73.01% and 72.22%, respectively. On Kaplan-Meier analysis, neonates with SI > cut-off showed a higher 30 day-mortality than those with low SI (P = 0.096). On multivariate analysis, the factor associated with mortality in our cohort was Apgar score ≤3, while SI showed a trend toward significance. CONCLUSIONS: At day1, nCD64 is useful for the diagnosis of neonatal sepsis whereas mHLA-DR is beneficial for monitoring patients at a later time point. The SI is a marker of moderate diagnostic sensitivity and supplements the current arsenal of laboratory investigations to detect neonatal sepsis. As a marker of prognosis, a high SI shows a trend towards greater mortality. © 2015 Clinical Cytometry Society.

